Electronic stopping
electronic_stopping sets the option for doing a radiation cascade simulation where the electronic stopping will be taken into account and electronic energy loss will be calculated. The force equation is modified by a friction-like term which is given as follows:
[math]\displaystyle{ \mathbf{F}_I = -\mathbf{\nabla}_IU - S_e\frac{\mathbf{v}_I}{v_I} }[/math].
The electronic stopping powers [math]\displaystyle{ S_e }[/math] are provided through an input data file, see related keyword estop_filename.
This is typically invoked while simulating collision cascades of atoms. There are a few input keywords for which typically inputs need to be provided if this calculation is invoked. These are as follows:
eel_cut, eel_freq_out, estop_filename, eel_E_prev_time, eel_md_prev_time, eel_md_last_step
Summary
| Required/optional | Type | Accepted values | Default | See also | Remarks |
|---|---|---|---|---|---|
| Optional | Boolean | .true. or .false.
|
.false.
|
eel_groupID, eel_cut, eel_freq_out, estop_filename, eel_E_prev_time, eel_md_prev_time, eel_md_last_step
|
Required functionality for simulating collision cascades |
Example
electronic_stopping = .true. eel_groupID = all ! Must mention if it acts for a specific group of atoms; 'all' is default and need not be mentioned. eel_cut = 1.0 ! in eV eel_freq_out = 10 estop_filename = 'stopping-data-file'